Technical data
Housing
Protection rating (EN 60529)
  • W/P to IP 65 & Explosion proof, Class 1, Div. 2, Gas Groups B, C & D (ExII2G, Eex d IIC T6)
Enclosure material
  • Die cast aluminum
Mounting
  • Bottom / Panel
Optional
  • 2” pipe mounting
Temperature
Ambient temperature
  • -10 to 60 °C
Media temperature
  • maximum up to 150 °C
Wetted parts
Process connection material
  • Stainless steel AISI 316
Optional
  • AISI 316L
Performance
Min. pressure range
  • 5 to 60 bar
Max. pressure range
  • 4 to 400 bar
Repeatability
  • ± 1% F. S
Technical Data
Adjustment
Set point
  • Between 20 to 80% F.S.
Differential
  • Fixed
Approval / Conformities
  • Explosion proof enclosure
Downloads
Data Sheet
To the top