Technical data
Temperature
  • |t| = absolute value °C
Technical Data
  • Temperature range: –200 to 600 °C (–328 to 1112 °F) according to IEC 60751
  • Spring loaded design for positive contact with thermowell
  • Variety of process connections & sheath diameters
  • Head mounted transmitter analogue (4-20mA) & communication protocol (HART)
Application
  • Universal range of application
  • Measuring range: –200 to 600 °C (–328 to 1112 °F)
  • Degree of protection up to IP68
  • Hazardous area classifications: Flameproof Exd-IIA/IIB-T6 & Explosionproof Exd-IIC-T6
Accuracy
Class AA:
  • ± (0.1 + 0.0017 · |t| )
Class A:
  • ± (0.15 + 0.002 · |t| )
Class B:
  • ± (0.3 + 0.005 · |t| )
Ambient Conditions
Ambient conditions
  • -40 to 85 °C
Downloads
Data Sheet
To the top