Technical data
Temperature
  • |t| = absolute value °C
Technical Data
  • Temperature range: –200 to 600 °C (–328 to 1112 °F) according to IEC 60751
  • Variety of process connections & sheath diameters
  • Various Cable options: PVC/PTFE/Silicon/Fiber Glass suitable for customer processes.
  • Anti-kink Spring to protect the connecting cable
Application
  • Mineral insulation enables flexibility and Durability.
  • RTD with adjustable process connection for adjustable insertion length.
  • Reference Standard : IEC 60751 / DIN 43760
  • The resistance thermometer is suitable for temperature measurement in machinery, laboratory equipment and plants with gaseous or liquid media such as air, water, oil, etc.
Accuracy
Class AA:
  • ± (0.1 + 0.0017 · |t| )
Class A:
  • ± (0.15 + 0.002 · |t| )
Class B:
  • ± (0.3 + 0.005 · |t| )
Ambient Conditions
Ambient conditions :
  • -40 to 85 °C