Temperature
  • |t| = absolute value °C
Technical Data
  • Temperature range: –50 to +200 °C (–58 to +392 °F) according to IEC 60751
  • Variety of process connections & sheath diameters
  • Various process connections Tri-clover Flange, Ingold, SMS
  • Head mounted transmitter analogue (4-20mA) & communication protocol (HART)
Application
  • Universal range of application
  • Measuring range: –50 to +200 °C (–58 to +392 °F)
  • Degree of protection up to IP68
  • Terminal head MOC: Die Cast Aluminum, SS316L
Accuracy
Class AA:
  • ± (0.1 + 0.0017 · |t| )
Class A:
  • ± (0.15 + 0.002 · |t| )
Class B:
  • ± (0.3 + 0.005 · |t| )
Ambient Conditions
Ambient conditions
  • -40 to 85 °C